Riello Catalogo 2026

LUNGHEZZA MASSIMA DEGLI SCARICHI FUMI (metri) Denominazione commerciale Intubamento Ø50 (1) Intubamento Ø60 (1) Coassiale Ø60/100 (2) Coassiale Ø80/125 (2) Sdoppiato Ø80 (2) Classificazione UNI 10642 Apparecchi CALDAIE MURALI A CONDENSAZIONE Family HM / Family HM Connect 25 50 74 10 25 69+69 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Family HM / Family HM Connect 30 11 34 8 20 36+36 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Family HM / Family HM Connect 35 11 34 8 20 36+36 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Family Externa 25 24 65 10 26 33+33 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Family Externa 30 21 53 4,85 12 27+27 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Family Aqua 3.5 – – 7,85 14,25 40+40 B23, C13, C23, C33, C43, C53, C63, C83 Residence HM 20 28 74 10 25 69+69 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Residence HM 25 28 74 10 25 69+69 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Residence HM 30 11 34 8 20 36+36 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Residence HM 35 11 34 8 20 36+36 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Termoduetto Condens – – 7,85 25 36+36 B23P, B53P, C13, C23, C33, C43, C53, C63, C83 Start 15 27 63 5,85 14 33+33 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Start 25 / Residence In 25 27 63 5,85 14 33+33 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Start 30 / Residence In 30 21 53 4,85 12 27+27 B23P-B53P-C13-C13x-C33-C33x-C43- C43x-C53-C53x-C63-C63x-C83-C83x- C93-C93x-C(10) Start Aqua Condens – – 7,85 14,8 B23P, B53P, C13, C23, C33, C43, C53, C63, C83 (1) Regolare i giri del ventilatore e usare solo tubi di scarico in classe H1. (2) Massima come somma dei condotti in metri. Le tabelle riportano le lunghezze rettilinee ammesse; l’inserimento di ogni eventuale curva le riduce di 0,8 m. Prodotti detraibili solo nell'ambito del rifacimento dell'impianto e della riqualificazione energetica dell'edificio. Si prega pertanto di verificarne sempre le specifiche modalità di accesso all'incentivo. RISCALDAMENTO CENTRALIZZATO POMPE DI CALORE ARIA ACQUA CALDAIE MURALI CALDAIE A BASAMENTO SCALDA ACQUA SOLARE TERMICO E BOLLITORI CLIMATIZZAZIONE UNITA’ TERMINALI COMPLEMENTI D’IMPIANTO SISTEMI IBRIDI ARIA CALDA BRUCIATORI CATALOGO PRODOTTI EDIZIONE MARZO 2026 236

RkJQdWJsaXNoZXIy MTUzNjY=