Riello Catalogo Sistema Fotovoltaico 2026
DIMENSIONAMENTO IMPIANTO FOTOVOLTAICO IBRIDO PER EDIFICI RESIDENZIALI RESIDENZIALE Consumi prevalentemente serali Impianto suggerito CON batteria/e di accumulo Tetti a falda (inclinazione 20°) Tetti piani con struttura di sostegno (inclinazione 10°) Consumi elettrici ANNUI previsti (kWh)* Posizione geografica Esposizione impianto solare Impianto fotovoltaico suggerito Produ- zione specifica media Produzione attesa (kWh) Copertura attesa (%) Produ- zione specifica media Produzione attesa [kWh] Copertura attesa (%) Pannelli (kWp) Inverter (kW) Batteria (kWh) Alimentazione (Ph) Codice kit 1.800 NORD Italia SUD 3,0 3,6 5,0 1 20229269 ≈ 1.310 kWh / kWp 3.960 95 ≈ 1.230 kWh / kWp 3.707 94 2.640 3,0 3,6 5,0 1 20229269 3.960 86 3.707 85 4.400 5,0 5,0 5,0 1 20229277 6.591 73 6.174 72 6.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 7.855 82 7.366 80 8.000 7.855 70 7.366 68 8,0 8,0 15,0 3 20229300 10.670 84 9.988 82 10.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 7.855 61 7.366 60 8,0 8,0 15,0 3 20229300 10.670 76 9.988 74 12.000 10,0 10,0 15,0 3 20229302 13.389 72 12.534 71 14.000 12,0 10,0 20,0 3 (1x) 20229303 (2x) 20224569 15.976 76 15.018 74 oltre Contattare l’Ufficio Tecnico --- --- --- --- 1.800 SUD-EST SUD-OVEST 3,0 3,6 5,0 1 20229269 ≈ 1.270 kWh / kWp 3.826 94 ≈ 1.200 kWh / kWp 3.635 91 2.640 3,0 3,6 5,0 1 20229269 3.826 86 3.635 84 4.400 5,0 5,0 5,0 1 20229277 6.371 73 6.056 72 6.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 7.597 82 7.227 80 8.000 7.597 70 7.227 68 8,0 8,0 15,0 3 20229300 10.311 84 9.794 82 10.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 7.597 61 7.227 59 8,0 8,0 15,0 3 20229300 10.311 75 9.794 74 12.000 10,0 10,0 15,0 3 20229302 12.939 72 12.291 70 14.000 12,0 10,0 20,0 3 (1x) 20229303 (2x) 20224569 15.472 76 14.741 74 oltre Contattare l’Ufficio Tecnico --- --- --- --- 1.800 CENTRO Italia SUD 3,0 3,6 5,0 1 20229269 ≈ 1.390 kWh / kWp 4.180 96 ≈ 1.315 kWh / kWp 3.950 93 2.640 3,0 3,6 5,0 1 20229269 4.180 87 3.950 87 4.400 5,0 5,0 5,0 1 20229277 6.952 73 6.574 73 6.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 8.278 83 7.836 81 8.000 8.278 71 7.836 69 8,0 8,0 15,0 3 20229300 11.262 85 10.643 83 10.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 8.278 62 7.836 61 8,0 8,0 15,0 3 20229300 11.262 77 10.643 75 12.000 10,0 10,0 15,0 3 20229302 14.130 73 13.355 72 14.000 12,0 10,0 20,0 3 (1x) 20229303 (2x) 20224569 16.775 77 15.937 75 oltre Contattare l’Ufficio Tecnico --- --- --- --- 1.800 SUD-EST SUD-OVEST 3,0 3,6 5,0 1 20229269 ≈ 1.330 kWh / kWp 3.989 95 ≈ 1.275 kWh / kWp 2.556 92 2.640 3,0 3,6 5,0 1 20229269 3.989 86 3.846 84 4.400 5,0 5,0 5,0 1 20229277 6.636 72 6.403 72 6.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 7.906 82 7.634 81 8.000 7.906 70 7.634 69 8,0 8,0 15,0 3 20229300 10.747 84 10.362 83 10.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 7.906 61 7.634 60 8,0 8,0 15,0 3 20229300 10.747 75 10.362 75 12.000 10,0 10,0 15,0 3 20229302 13.485 71 13.003 71 14.000 12,0 10,0 20,0 3 (1x) 20229303 (2x) 20224569 16.063 76 15.545 75 oltre Contattare l’Ufficio Tecnico --- --- --- --- 1.800 SUD Italia SUD 3,0 3,6 5,0 1 20229269 ≈ 1.470 kWh / kWp 4.399 96 ≈ 1.400 kWh / kWp 4.192 94 2.640 3,0 3,6 5,0 1 20229269 4.399 87 4.192 86 4.400 5,0 5,0 5,0 1 20229277 7.312 73 6.974 73 6.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 8.701 83 8.306 82 8.000 8.701 71 8.306 70 8,0 8,0 15,0 3 20229300 11.853 85 11.298 84 10.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 8.701 63 8.306 62 8,0 8,0 15,0 3 20229300 11.853 77 11.298 76 12.000 10,0 10,0 15,0 3 20229302 14.871 73 14.175 72 14.000 12,0 10,0 20,0 3 (1x) 20229303 (2x) 20224569 17.573 77 16.855 76 oltre Contattare l’Ufficio Tecnico --- --- --- --- 1.800 SUD-EST SUD-OVEST 3,0 3,6 5,0 1 20229269 ≈ 1.390 kWh / kWp 4.151 95 ≈ 1.350 kWh / kWp 4.056 94 2.640 3,0 3,6 5,0 1 20229269 4.151 85 4.056 84 4.400 5,0 5,0 5,0 1 20229277 6.901 71 6.749 72 6.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 8.215 81 8.040 81 8.000 8.215 69 8.040 69 8,0 8,0 15,0 3 20229300 11.182 84 10.930 83 10.000 6,0 6,0 10,0 1/3 (1Ph) 20229286 (3Ph) 20229287 8.215 61 8.040 61 8,0 8,0 15,0 3 20229300 11.182 75 10.930 75 12.000 10,0 10,0 15,0 3 20229302 14.030 70 13.715 71 14.000 12,0 10,0 20,0 3 (1x) 20229303 (2x) 20224569 16.654 75 16.348 75 oltre Contattare l’Ufficio Tecnico --- --- --- --- Le informazioni presenti nella tabella NON SOSTITUISCONO i calcoli di un Tecnico Abilitato per il corretto dimensionamento e stima della copertura attesa. (*) Consumi elettrici annui previsti (kWh): sono la somma dei consumi elettrici stimati della pompa di calore e dei consumi elettrici annui rilevati in bolletta. CATALOGO EDIZIONE MAGGIO 2026 38
Made with FlippingBook
RkJQdWJsaXNoZXIy MTUzNjY=