Riello Catalogo Sistema Fotovoltaico 2026
COMMERCIALE Consumi prevalentemente diurni Impianto suggerito SENZA batteria/e di accumulo Tetti piani con struttura di sostegno (inclinazione 10°) Consumi elettrici ANNUI previsti (kWh)* Posizione geografica Esposizione impianto solare Impianto fotovoltaico suggerito Produzione specifica media Produzione attesa [kWh] Copertura attesa (%) Pannelli (kWp) Inverter (kW) Batteria (kWh) Alimentazione (Ph) Codice kit 10.000 NORD Italia SUD 6,0 6,0 --- 1/3 --- ≈ 1.230 kWh / kWp 7.366 42 8,0 8,0 --- 3 --- 9.988 43 15.000 10,0 10,0 --- 3 --- 12.534 43 12,0 10,0 --- 3 --- 15.018 45 20.000 kWh 16,0 16,0 --- 3 --- 19.975 45 25.000 kWh 20,0 20,0 --- 3 --- 24.997 45 30.000 kWh 25,0 25,0 --- 3 --- 31.289 45 40.000 kWh 30,0 30,0 --- 3 --- 37.580 44 oltre Contattare l’Ufficio Tecnico --- --- 10.000 SUD-EST SUD-OVEST 6,0 6,0 --- 1/3 --- ≈ 1.200 kWh / kWp 7.227 42 8,0 8,0 --- 3 --- 9.794 43 15.000 10,0 10,0 --- 3 --- 12.291 43 12,0 10,0 --- 3 --- 14.741 45 20.000 kWh 16,0 16,0 --- 3 --- 19.588 45 25.000 kWh 20,0 20,0 --- 3 --- 24.582 45 30.000 kWh 25,0 25,0 --- 3 --- 30.804 45 40.000 kWh 30,0 30,0 --- 3 --- 37.050 44 oltre Contattare l’Ufficio Tecnico --- --- 10.000 CENTRO Italia SUD 6,0 6,0 --- 1/3 --- ≈ 1.315 kWh / kWp 7.836 43 8,0 8,0 --- 3 --- 10.643 44 15.000 10,0 10,0 --- 3 --- 13.355 44 12,0 10,0 --- 3 --- 15.937 46 20.000 kWh 16,0 16,0 --- 3 --- 21.283 46 25.000 kWh 20,0 20,0 --- 3 --- 26.633 46 30.000 kWh 25,0 25,0 --- 3 --- 33.333 46 40.000 kWh 30,0 30,0 --- 3 --- 40.033 45 oltre Contattare l’Ufficio Tecnico --- --- 10.000 SUD-EST SUD-OVEST 6,0 6,0 --- 1/3 --- ≈ 1.275 kWh / kWp 7.634 42 8,0 8,0 --- 3 --- 10.362 44 15.000 10,0 10,0 --- 3 --- 13.003 43 12,0 10,0 --- 3 --- 15.545 45 20.000 kWh 16,0 16,0 --- 3 --- 20.699 45 25.000 kWh 20,0 20,0 --- 3 --- 25.975 45 30.000 kWh 25,0 25,0 --- 3 --- 32.482 45 40.000 kWh 30,0 30,0 --- 3 --- 39.038 44 oltre Contattare l’Ufficio Tecnico --- --- 10.000 SUD Italia SUD 6,0 6,0 --- 1/3 --- ≈ 1.400 kWh / kWp 8.306 43 8,0 8,0 --- 3 --- 11.298 44 15.000 10,0 10,0 --- 3 --- 14.175 44 12,0 10,0 --- 3 --- 16.855 46 20.000 kWh 16,0 16,0 --- 3 --- 22.590 46 25.000 kWh 20,0 20,0 --- 3 --- 28.268 46 30.000 kWh 25,0 25,0 --- 3 --- 35.377 46 40.000 kWh 30,0 30,0 --- 3 --- 42.486 45 oltre Contattare l’Ufficio Tecnico --- --- 10.000 SUD-EST SUD-OVEST 6,0 6,0 --- 1/3 --- ≈ 1.350 kWh / kWp 8.040 42 8,0 8,0 --- 3 --- 10.930 45 15.000 10,0 10,0 --- 3 --- 13.715 43 12,0 10,0 --- 3 --- 16.348 45 20.000 kWh 16,0 16,0 --- 3 --- 21.810 45 25.000 kWh 20,0 20,0 --- 3 --- 27.367 45 30.000 kWh 25,0 25,0 --- 3 --- 34.160 45 40.000 kWh 30,0 30,0 --- 3 --- 41.025 44 oltre Contattare l’Ufficio Tecnico --- --- Le informazioni presenti nella tabella NON SOSTITUISCONO i calcoli di un Tecnico Abilitato per il corretto dimensionamento e stima della copertura attesa. (*) Consumi elettrici annui previsti (kWh): sono la somma dei consumi elettrici stimati della pompa di calore e dei consumi elettrici annui rilevati in bolletta o previste per l’attività specifica. DIMENSIONAMENTO IMPIANTO FOTOVOLTAICO PER ATTIVITÀ COMMERCIALI CATALOGO EDIZIONE MAGGIO 2026 41
Made with FlippingBook
RkJQdWJsaXNoZXIy MTUzNjY=